Portable Patient Monitor 12.1 Inch Color with 6 Standard Parameter Price in Bangladesh

(4.5) 4 Reviews | 6 Orders | 1 Wish Listed
$ $
Quantity
Color

Brand: Yunker

Category: Medical Equipment

Stock: In Stock

Code: #10311

Portable Patient Monitor 12.1 Inch Color with 6 Standard Parameters:

Features:   

  • Ergonomic design, portable, convenient for use
  • 12.1″ TFT display, configurable up to 8 waveforms, enables maximum data visibility for the most critical parameters
  • Unique digital SPO2 technology can work accurate during motion and low perfusion
  • Anti-AC & high-frequency electrosurgical & defibrillator interference
  • Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead, and others
  • Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events
  • ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis, and calculation
  • Audible & visual alarm available, adjustable
  • Patient information management function
  • Powerful software function to support use in NICU, ICU, OR, CCU or normal patient room
  • Optional software upgrading based on USB
  • Wired/wireless networking with central monitoring system, up to 64 beds in one group
  • Built-in 3 trace thermal recorder for printing real-time and historical data
  • Multi-language i.e. English, Spanish, Turkish.
  • Super long life rechargeable Lithium battery up to 4 hours of working time
  • Suitable for adult, pediatrics, and neonate patients

Standard configuration:

  • ECG, NIBP, SPO2, TEMP, RESP, PR, Rechargeable Lithium battery

Optional:

  • Dual TEMP
  • Dual IBP
  • ETCO2 (side stream)
  • Thermal recorder
  • Wall mount
  • Trolley

Portable Patient Monitor

 
ECG

 

Full lead: I, II, III, AVL, AVR, AVF and V
Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
Band width: 0.05Hz-100Hz(3dB)
Heart rate:
Scope: 15 times/minute to 300 times/minutes
Accuracy:  ±1 time/minute
Variation of heartbeat LORENZO drawing: Analysis on heartbeat data for the current 5 minutes with histogram during RR period.
Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.
Accuracy: Error rate < 20%
Undetected rate < 20%
ST section
Scope:     ±0.8mV
Precision:  < ±0.05mV

SpO2

Detection scope:   0%-100%
Accuracy                 ±1%     90%-100%
±2%      70%-89%

NIBP 

Theory Electric oscillator
Cuff gassing time   less than 15 seconds
First-time gassing pressure: dynamic state 24kPa(180 mmHg)
Manual selection: 9.3kPa(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg)
18.6kPa(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg),
Automatic detection period: 1 minute to 240 minutes
Stop size:1 min(1 min -10min), 5min(10 min -30min), 10min(30 m
in -90min) and 30min(90 min -240min)
Detection scope:
Systolic blood pressure:   4kPa -34kPa(30mmHg -255mmHg)
Diastolic pressure             2kPa -29.3kPa(15mmHg -220mmHg)
Mean pressure               2.7kPa~31.3kPa       (20mmHg~235mmHg)
Detection accuracy
Static pressure: ±3mmHg
Pulse rate:  ±2%

Portable Patient Monitor

Resp

Chest impedance method or concentration of carbon dioxide at end of respiration
Scope of chest impedance method     0 time/minute – 100 minutes/minute
The precision of chest impedance method  time/minute
Detection scope of carbon-oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol
Detection scope of respiration rate: 2 times/minute ->60 times/minute(including baby)
Detection precision of respiration rate: ±1 time/minute

Temp

Single/double path
Type:    Vascular/surface temperature
Scope:    20℃~50℃
Accuracy:  ±0.2℃

Invasive blood pressure (optional)

Single/double path
Type: direct and continuous detection
Scope: -6.67kPa(-50mmHg)—46.67kPa(350mmHg)
Precision: below 13.33kPa(100mmHg) ±0.27kPa(2mmHg)  13.33k
Pa(100mmHg) above ±2%
Frequency response:DC-12Hz
Input resistance: not less than 500kΩ
Sensitivity of sensor: 5μV/V/mmHg
Motivation voltage:5V (DC)
Accuracy of sensor: ±2%Isolation voltage: 4 kV

How students rated this courses

4.5

(Based on 27 reviews)

53%
36%
9%
3%
2%

Reviews

avatar

Max Hawkins 2 Days ago

Lectures were at a really good pace and I never felt lost. The instructor was well informed and allowed me to learn and navigate Figma easily.

Was this review helpful?

Yes No
avatar

Arthur Williamson 3 Days ago

Its pretty good.Just a reminder that there are also students with Windows, meaning Figma its a bit different of yours. Thank you!

Was this review helpful?

Yes No
avatar

Claire Jones 4 Days ago

Great course for learning Figma, the only bad detail would be that some icons are not included in the assets. But 90% of the icons needed are included, and the voice of the instructor was very clear and easy to understood.

Was this review helpful?

Yes No
avatar

Bessie Pena 5 Days ago

I have really enjoyed this class and learned a lot, found it very inspiring and helpful, thank you!

Was this review helpful?

Yes No

Portable Patient Monitor 12.1 Inch Color with 6 Standard Parameters:

Features:   

  • Ergonomic design, portable, convenient for use
  • 12.1″ TFT display, configurable up to 8 waveforms, enables maximum data visibility for the most critical parameters
  • Unique digital SPO2 technology can work accurate during motion and low perfusion
  • Anti-AC & high-frequency electrosurgical & defibrillator interference
  • Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead, and others
  • Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events
  • ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis, and calculation
  • Audible & visual alarm available, adjustable
  • Patient information management function
  • Powerful software function to support use in NICU, ICU, OR, CCU or normal patient room
  • Optional software upgrading based on USB
  • Wired/wireless networking with central monitoring system, up to 64 beds in one group
  • Built-in 3 trace thermal recorder for printing real-time and historical data
  • Multi-language i.e. English, Spanish, Turkish.
  • Super long life rechargeable Lithium battery up to 4 hours of working time
  • Suitable for adult, pediatrics, and neonate patients

Standard configuration:

  • ECG, NIBP, SPO2, TEMP, RESP, PR, Rechargeable Lithium battery

Optional:

  • Dual TEMP
  • Dual IBP
  • ETCO2 (side stream)
  • Thermal recorder
  • Wall mount
  • Trolley

Portable Patient Monitor

 
ECG

 

Full lead: I, II, III, AVL, AVR, AVF and V
Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
Band width: 0.05Hz-100Hz(3dB)
Heart rate:
Scope: 15 times/minute to 300 times/minutes
Accuracy:  ±1 time/minute
Variation of heartbeat LORENZO drawing: Analysis on heartbeat data for the current 5 minutes with histogram during RR period.
Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.
Accuracy: Error rate < 20%
Undetected rate < 20%
ST section
Scope:     ±0.8mV
Precision:  < ±0.05mV

SpO2

Detection scope:   0%-100%
Accuracy                 ±1%     90%-100%
±2%      70%-89%

NIBP 

Theory Electric oscillator
Cuff gassing time   less than 15 seconds
First-time gassing pressure: dynamic state 24kPa(180 mmHg)
Manual selection: 9.3kPa(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg)
18.6kPa(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg),
Automatic detection period: 1 minute to 240 minutes
Stop size:1 min(1 min -10min), 5min(10 min -30min), 10min(30 m
in -90min) and 30min(90 min -240min)
Detection scope:
Systolic blood pressure:   4kPa -34kPa(30mmHg -255mmHg)
Diastolic pressure             2kPa -29.3kPa(15mmHg -220mmHg)
Mean pressure               2.7kPa~31.3kPa       (20mmHg~235mmHg)
Detection accuracy
Static pressure: ±3mmHg
Pulse rate:  ±2%

Portable Patient Monitor

Resp

Chest impedance method or concentration of carbon dioxide at end of respiration
Scope of chest impedance method     0 time/minute – 100 minutes/minute
The precision of chest impedance method  time/minute
Detection scope of carbon-oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol
Detection scope of respiration rate: 2 times/minute ->60 times/minute(including baby)
Detection precision of respiration rate: ±1 time/minute

Temp

Single/double path
Type:    Vascular/surface temperature
Scope:    20℃~50℃
Accuracy:  ±0.2℃

Invasive blood pressure (optional)

Single/double path
Type: direct and continuous detection
Scope: -6.67kPa(-50mmHg)—46.67kPa(350mmHg)
Precision: below 13.33kPa(100mmHg) ±0.27kPa(2mmHg)  13.33k
Pa(100mmHg) above ±2%
Frequency response:DC-12Hz
Input resistance: not less than 500kΩ
Sensitivity of sensor: 5μV/V/mmHg
Motivation voltage:5V (DC)
Accuracy of sensor: ±2%Isolation voltage: 4 kV

01610038610